Cooling Capacity (95° at 60% RH) (Btu/Hr) |
1 Ton 12,000 |
Air Flow (CFM, High/Low) Evaporator |
410/380 |
Air Flow (CFM, High/Low) Condenser |
820/715 |
Operating Conditions (Min-Max) (at 50% RH) |
65°-95°F |
Voltage |
115/1 |
Cooling Capacity (95° at 60% RH) (Btu/Hr) |
1.5 Ton 16,800 |
Air Flow (CFM, High/Low) Evaporator |
540/500 |
Air Flow (CFM, High/Low) Condenser |
770/710 |
Operating Conditions (Min-Max) (at 50% RH) |
65°-95°F |
Voltage |
115/1 |
Cooling Capacity (95° at 60% RH) (Btu/Hr) |
2 Ton 24,000 |
Air Flow (CFM, High/Low) Evaporator |
630/545 |
Air Flow (CFM, High/Low) Condenser |
870/760 |
Operating Conditions (Min-Max) (at 50% RH) |
65°-95°F |
Voltage |
208-230/1 |
Cooling Capacity (95° at 60% RH) (Btu/Hr) |
3 Ton 36,000 |
Air Flow (CFM, High/Low) Evaporator |
990/825 |
Air Flow (CFM, High/Low) Condenser |
1490/1060 |
Operating Conditions (Min-Max) (at 50% RH) |
65°-95°F |
Voltage |
208-230/1 |
Cooling Capacity (95° at 60% RH) (Btu/Hr) |
5 Ton 60,000 |
Air Flow (CFM, High/Low) Evaporator |
1940/1770 |
Air Flow (CFM, High/Low) Condenser |
2830/2650 |
Operating Conditions (Min-Max) (at 50% RH) |
65°-105°F |
Voltage |
208-230/1 |
Cooling Capacity (95° at 60% RH) (Btu/Hr) |
5 Ton 60,000 |
Air Flow (CFM, High/Low) Evaporator |
1940/1770 |
Air Flow (CFM, High/Low) Condenser |
2830/2650 |
Operating Conditions (Min-Max) (at 50% RH) |
65°-105°F |
Voltage |
460/3 |
Cooling Capacity (95° at 60% RH) (Btu/Hr) |
10500 |
Air Flow (CFM, High/Low) Evaporator |
324/228 |
Air Flow (CFM, High/Low) Condenser |
700/370 |
Operating Conditions (Min-Max) (at 50% RH) |
65° - 95° F (Evaporator) - 65° - 113° F (Condenser) |
Voltage |
115/1 |
Cooling Capacity (95° at 60% RH) (Btu/Hr) |
25000 |
Air Flow (CFM, High/Low) Evaporator |
950/800 |
Air Flow (CFM, High/Low) Condenser |
1600/1300 |
Operating Conditions (Min-Max) (at 50% RH) |
65° - 95° F (Evaporator) - 50° - 113° F (Condenser) |
Voltage |
208-230/1 |
Centralized air conditioning is often not enough to maintain the required server room temperature. Our portable server coolers and wall-mounted (standard drop ceiling) data room air conditioners are specifically designed for offices and spaces filled with expensive, heat-generating electronics. Server rooms must almost always be kept at cool temperatures -- computers, networks, communications and office equipment will shut down when the temperature rises, crippling operations for days if not weeks. Spot Coolers provides a full suite of server room cooling systems to ensure your servers can operate smoothly and efficiently, whether it’s a small data room, network closet or other IT environment.
Our server room ac units safely and effectively address complex data room cooling requirements, saving money while protecting your company's investment in equipment and customers. These small server room air conditioners can pump cool air inside or outside an overheated rack cabinet enclosure, as well as on an equipment hotspot. Our portable air conditioning units are self-contained, requiring no costly or complicated installation. Just plug in one of our many commercial data room cooling units, set the thermostat to the desired temperature and feel the temperature drop!